Page 11 - Tower Catalog
P. 11

Applica on: La ce towers
Size: 7' 6" (2.3 m) or 14' 6" (4.4 m) face
Design: Frame with 52" (1.3 m) stand-off
Feature: Angle design, dual gated 52" (1.3 m) stand-off
Mounts to: Straight or tapered legs up to 8" OD, 8" angle 60o, or 6" angle 90o Material: Hot dip galvanized steel
Includes: Frame, clamps, and s ff arm
Order Separately: Pipe (pg 50)
La ce and Guyed Tower
Tower Stand-off Sector Frames
Mfr Part # SF-SU7-B
Descrip on Weight, lb 7' 6" (2.3 m) 334 10' 6" (3.1 m) 353 12' 6" (3.8 m) 368 14' 6" (4.4 m) 383
EPA EPA
(no ice, sq  ) (1/2" radial ice, sq  )
Man Ra ng: 250 lb ver cal man load at 15 mph (BWS)
Wind Ra ng*: 120 mph (BWS) per latest
version of TIA/EIA-222 140 mph 3-second gust, Expo- sure ā€œDā€ per FBC, at 150' AGL
Face Width
7' 6" Face
15.1 19.5
10' 6" Face
12' 6" Face
16.8 21.9
18.2 23.6
14' 6" Face
19.5 25.4
SF-SU10-B
SF-SU12-B
SF-SU14-B
NOTE: Pipe is ordered separately; see page 50.
Lightweight T Frames
*Typical installa on of (4) 72" x 8" panel antennas per sector
Applica on: La ce Towers
Size: 10'-6" Face or 12'-6" Face Design: Welded Frame
Feature: Bolt together face
Mounts to: 4-1/2" OD round legs Material: Hot dip galvanized steel Includes: Frame and hardware
Order Separately: Pipe mount (pg 13), antenna moun ng pipes (pg 50)
Weight, lb
336 346
Mfr Part # Descrip on
La ce Tower T-Frame Base Kit
800089A with 10'-6" face, for 4-1/2" OD straight legs
Andrew
Solu ons 803444A with 12'-6" face, for 4-1/2" OD straight legs NOTE: Pipe is ordered separately; see page 50.
For tapered pipe mount, see page 13.
Tower Pipe Frame
Applica on: La ce towers
Size: 10' 6" (3.1 m) to 12' 6" (3.8 m)
Design: 2-3/8" (60.3 mm) OD pipe with crossover plates
Feature: Flush or pipe mounted sector frame
Mounts to: 1-1/2" to 4-1/2" (38.1 mm to 114.3 mm) OD
Material: Hot dip galvanized steel
Includes: Frame and s ff arm
Order Separately: Pipe (pg 50) and pipe frame stand-off bracket (pg 15)
EPA
(no ice, sq  )
Mfr Part # Descrip on Weight, lb
EPA
(1/2" radial ice, sq  )
Face Width
SF-TP10-B 10' 6" (3.1 m) 240
Andrew
Solu ons SF-TP12-B 12' 6" (3.8 m) 255 NOTE: Pipe is ordered separately; see page 50.
For pipe frame stand-off brackets, see page 15.
12' 6" Face 10.8
14' 6" Face 11.7
Man Ra ng: 250 lb ver cal man load at 15 mph
(BWS)
Wind Ra ng*: 120 mph (BWS) per latest version of TIA/EIA-222 140 mph 3-second gust, Exposure ā€œDā€ per
FBC, at 150' AGL
*Typical installa on of (3) 72" x 8" panel antennas per sector
15.1 16.4
11
Andrew Solu ons