Non-Penetra ng Roof Frames
Non-Penetra ng Roof Mount
Roof-Top
Applica on: Roof-top
Size: 7' (2.1 m) to 14' 6" (4.4 m) face Design: Single sector
roof mount
Feature: Complete kit
Material: Hot dip
galvanized steel
Includes: Rubber mats,
frames, and hardware
Order Separately: Pipe
(pg 50)
Applica on: Roof-top
Size: 35" (0.9 m) square base
Design: Non-penetra ng
Feature: Simple bolt together design Material: Hot dip galvanized steel Includes: Mast, supports, and ballast tray Order Separately: Rubber mats (pg 31)
Weight, Mfr Part # Descrip on lb
RF-N7-B
7' (2.1 m) wide, 2-3/8" (60.3 mm) OD
341.3
Mfr Part # RM-SM190-60
RM-SM238-60
Descrip on
1.9" OD x 60"
(48.3 mm OD x 1.5 m) Pipe 2-3/8" OD x 60"
(60.3 mm OD x 1.5 m) Pipe
Weight, lb 60
66
RF-N10-B
10' 6" (3.2 m) wide, 2-3/8" (60.3 m) OD
356.3
RF-N12-B RF-N14-B
12' 6" (3.8 m) wide, 2-3/8" (60.3 mm) OD
372.0 374.0
Roof-Top Mount
14' 6" (4.5 m) wide, 2-3/8" (60.3 mm) OD
Applica on: Roof-top
Size: 11' (3.4 m) face
Design: Single sector roof mount, 2-3/8" (60.3 mm) OD design Feature: Adjustable face design Material: Hot dip galvanized steel Includes: Mount
Order Separately: Pipe (pg 50), crossover kits (pg 18), and anchors (pgs 64-66)
RF-TDK
Non-Penetra ng Sled Tie-Down Kit,
30
2 needed for RF-N Series Exposure ā€œCā€ per UBC, at 100' AGL
NOTE: Pipe is ordered separately; see page 50.
Wind Ra ng*: 85 mph (BWS) per latest revision of TIA/EIA-222
*Typical installa on of (4) 120" x 8" panel antennas per sector
Mul -Sector Roof Frames
Applica on: Roof-top
Size: 10' (3 m) face
Design: Triangular 3-sector frame Feature: Single moun ng solu on Mounts to: Penetra ng or non-penetra ng
Material: Hot dip galvanized steel Includes: Mount and u-bolts Order Separately: Moun ng pipes (pg 50), sled kit, and rubber mats (below)
Andrew Solu ons
TP-100 383
Mfr Part # Weight, lb
Mfr Part # MT-180 MT-181
Weight, Descrip on lb
Feature: Adjustable face design Material: Hot dip galvanized steel Includes: Mount
Order Separately: Pipe (pg 50), crossover kits (pg 18), and anchors (pgs 64-66)
Assembled MT-180 & MT-181
Applica on: Roof-top, penetra ng Size: 12' 6" (3.8 m) face
Design: Triangular 3-sector frame, 2-3/8" OD design
Mul -Sector Roof Frame. Order
2-3/8" (60.3 mm) OD pipes separately 465.6
Mul -Sector Roof-Top Mount
Non-Penetra ng Sled Kit for Mul -Sec-
tor Roof Frame 190.3
Rubber Mat, 1/2" x 18" x 48"
Mfr Part # Weight, lb
6 mats required for sled kit 16.2 *Addi onal roof frame sizes available; contact Primus for more informa on
MT-F1637*
Andrew Solu ons
TP-300 568.6